42 Turning a Zone On or Off
4. Enter the new setpoint, and then touch Enter.
The operator can also add or subtract from the current setpoint by entering the number
and then touching the + or - button. For example, to add 4 degrees to the selected zones
setpoint touch the 4 button followed by the + button.
5. Touch OK.
7.2.2 Turning a Zone On or Off
Neo2 allows the operator to set each zone to On or Off. Zones that are On apply power to the
heater and zones that are Off do not.
It may be necessary to run a mold with one or more zones turned off.
To turn a zone off:
1. On the Quick Set screen, touch the zone to adjust.
To select more than one zone, touch the additional zones and they will be selected.
2. Using the Parameter Scroll buttons, scroll to ZONE.
3. Touch ON or OFF to toggle the selected zones from ON to OFF or vice versa.
4. Touch OK.