I/O Box Options (Outputs) 89
User Guide v 1.4 — September 2015 System Options
11.3.3 I/O Box Options (Outputs)
The Output options that can be purchased are listed below, along with a description of each.
Some of these options are part of the Remote Load option. All outputs are dry contacts;
whatever you put in, you will get out when the output is activated.
Table 11-5 I/O Box Options (Inputs)
Option Name Description
R. STANDBY If the R. STANDBY (Remote Standby) digital input option is turned on, it
will place all zones that have a Remote Standby setpoint set into the
Standby mode whenever this input signal gets activated.
R. BOOST If the R. BOOST (Remote Boost) digital input option is turned on, it will
place all zones that have a Remote Boost setpoint set into the Boost
mode whenever this input signal gets activated.
R. START If the R. START (Remote Start) digital input option is turned on, it will
START the system whenever this signal is remotely activated. This state
will remain until the STOP button is selected or Remote Stop is activated.
R. STOP If the R. STOP (Remote Sto)p digital input option is turned on, it will STOP
the system whenever this signal is remotely activated. This state will
remain until the START button is selected or Remote Start is activated.
NOTE:You cannot start the system when this input is active.
M. BOOST If the M. BOOST (Remote Manual Boost) digital input option is turned on,
it will place all zones that have a Manual Boost setpoint set into the Boost
mode whenever this input signal gets activated. This acts just like
selecting the BOOST button in Neo2.
CAUTION!
Mechanical hazard - risk of damage to the equipment. DO NOT apply a voltage greater
than 120 VAC/VDC (1amp) to any of the Outputs. Doing so could damage the I/O Box or
Neo2.
Table 11-6 I/O Box Options (Outputs)
Option Name Description
ALARM RLY If the Alarm Error dry contact output option is turned on, it will be
activated when an Alarm or Abort condition occurs. This state will
remain until the alarm condition is CLEARED or RESET.
PCM RLY If the PCM dry contact output option is turned on, it will be activated
when an Abort condition occurs, and the PCM setting in the Quick Set
screen is set to System. This state will remain until the alarm condition is
CLEARED or RESET.