SPI Communication Protocol 95
User Guide v 1.4 — September 2015 System Options
11.6 SPI Communication Protocol
The SPI option allows the Neo2 to communicate with any central network or molding
machine that supports the Society of Plastics Industry (SPI) standard protocol.
Touch OPTIONS, and then SPI to open the SPI Communication screen.
Figure 11-5 SPI Communications Screen
Table 11-9 SPI Communication Screen Item Descriptions
Item Description
SPI ID The SPI device ID. The default is 26h and cannot be changed.
SPI Address The SPI address. Available settings are 32 to 254. The default is 32.
SPI Baud The SPI baud rate setting. Available settings are 1200, 2400, 4800, 9600,
and 19.2k. The default is 9600.
SPI Enabled The setting to turn SPI ON or OFF. Available settings are YES and NO. The
default is NO.
SPI Off The setting allows or prevents setup parameters to the injection
molding machine. Available settings are YES and NO. The default is YES.
SPI Save The setting allows or prevents permanent changes. Available settings
are YES (allows changes) and NO (prevents changes). The default setting
is YES.
SPI Monitor Access the SPI Communications Monitor screen.