v 1.4 — September 2015 Altanium Neo2
74 Standby Operation Description
9.4.1.4 Standby Operation Description
Manual Standby can be cancelled at any time by touching STANDBY or STOP buttons.
Table 9-1 Manual Standby Operational Description
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Cycle
Enabled
Operation - STANDBY Button
Select
0:00:00 ---- ---- ---- ---- System enters Standby indefinitely.
X:XX:XX ---- ---- ---- ---- System remains in Standby until the
timer expires.
Table 9-2 Remote Standby Operational Description
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Cycle
Enabled
Operation - STANDBY Button
Select
---- 0:00:00 0:00:00 Trigger ---- System will not enter Standby since no
timers are set.
---- 0:00:00 X:XX:XX Trigger ---- System immediately enters and
remains in Standby until the timer
expires.
---- X:XX:XX X:XX:XX Trigger No System delays for specified time and
then enters Standby until the timer
expires.
---- X:XX:XX 0:00:00 Trigger No System delays for specified time and
then enters Standby indefinitely.
---- X:XX:XX X:XX:XX Trigger Yes System delays for specified time and
then enters Standby until the timer
expires. If the input signal changes
state while delay timer is active, the
delay timer is reset to the specified
value.
---- X:XX:XX 0:00:00 Trigger Yes System delays for specified time and
then enters Standby indefinitely. If the
input signal changes state while the
delay timer is active, the delay timer is
reset to the specified value.
---- 0:00:00 0:00:00 ON/OFF ---- System enters Standby until the input
signal is not active.
---- 0:00:00 X:XX:XX ON/OFF ---- System enters Standby until the input
signal is not active or the timer expires.
---- X:XX:XX X:XX:XX ON/OFF ---- System delays for specified time and
then enters Standby until the signal is
not active or the timer expires