v 1.4 — September 2015 Altanium Neo2
12 Thermocouple Types and Color Codes
Ohm's Law says:
Example: If the resistance is 12.5 ohms, and the input voltage is 240 volts, you would
divide 240 by 12.5 to calculate the maximum amperage draw on that heating element:
240 / 12.5 = 19.2 amps
19.2 Amps x 240 volts = 4,608 watts.
In hot runner molding, some portions of Ohm's law are more useful than others. We have
only presented here those laws that apply.
2.4 Thermocouple Types and Color Codes
Amps = Watts / Volts Amps = Volts / Resistance
Resistance = Volts / Amps Watts = Volts x Amps
Input
voltage
24 V 110 V208 V220 V240 V
Resistance
20 Ω 20 Ω 20 Ω 20 Ω 20 Ω
Amperage
1.2 A 5.5 A 10.4 A 11.0 A 12.0A
Watts
28.8 W 605.0W 2163.2 W 2420 W 2880 W
Code Type
International
Color Code
(BS4937 Part
30:1993)
BRITISH
(BS1843:1952)
AMERICAN
ANSI
GERMAN DIN
J Iron/ Constantan/ (Copper-
Nickel)
Overall Black Overall Black Overall Black Overall Blue
+ ve - ve + ve - ve + ve - ve + ve - ve
Black White Yellow Blue White Red Red Blue
K Nickel- Chromium/ Nickel-
Aluminum
Overall Green Overall Red Overall Yellow Overall Green
+ ve - ve + ve - ve + ve - ve + ve - ve
Green White Brown Blue Yellow Red Red Green