44 Changing the Boost Setpoint
7.2.5 Changing the Boost Setpoint
It may be necessary to raise the temperatures in the mold for a period of time. Neo2 gives the
operator the ability to do this by touching one button without having to change the normal
setpoint. The boost temperature setpoint for the heaters must be specified, this value is used
when the BOOST button is touched. The default setting is NO CHANGE, which is displayed
as dashed lines (---).
To change a boost setpoint:
1. On the Quick Set screen, touch the zone to adjust.
To select more than one zone, touch the additional zones and they will be selected.
2. Using the Parameter Scroll buttons, scroll to BOOST SETPOINT.
3. Using the numerical keypad, enter the new setpoint, and then touch Enter.
The operator can also add or subtract from the current setpoint by entering the number
you want and then touching the + or - button. For example, to add 4 degrees to the
selected zones setpoint, touch the 4 button followed by the + button.
NOTE:Neo2 will remain in Boost until the BOOST button is touched again or until the
manual standby timer expires, if set.
7.3 Adjusting Advanced Parameters
This section describes how to set more advanced parameters such as alarm and abort bands,
sensor assignment, slaving zones and PID.
7.3.1 Naming a Zone
To name a zone:
1. On the Quick Set screen, touch the zone to adjust.
To select more than one zone, touch the additional zones and they will be selected.
2. Using the Parameter Scroll buttons, scroll to NAME.
3. Touch NAME and the Keyboard window appears.
IMPORTANT!
Entering a value of 0 will place the selected zones into a NO CHANGE (---) mode. When in this
mode, these zones will not change their setpoint when the BOOST button is touched.