Printing Reports to File 19
User Guide v 1.4 — September 2015 Neo2 Operator Interface
The following warnings and restrictions should be observed when using the USB port:
Only supports USB disks that use a File Allocation Table (FAT or FAT32) format.
Only supports USB versions 2.0 and 1.1.
Use an empty USB disk or one that contain as few files as possible.
4.4 Printing Reports to File
Neo2 has five reports available for printing. The data is printed directly to the USB drive in a
TEXT file format. A USB drive must be installed to enable the report buttons.
Zone Data Short — report for the currently loaded mold set up includes Zone Number,
Setpoint, Actual Temperature.
Zone Data Long — report for the currently loaded mold set up includes Zone Number,
Zone Name, Setpoint, Actual Temperature, Power, Amps, Alarm setting, Abort setting,
Regulation, Watts, VAC, and Ohms.
Mold Test Data — report for the currently loaded mold set up includes the mold test
results. This is only available if a mold test has been run previously.
Mold Setup Data — report for the currently loaded mold set up includes the mold setup
data.
Error Log — report for the 100 most current alarms.