EasyManua.ls Logo

Husky Altanium Neo2 - Chapter 10 Heating the Mold; Starting the Neo2 System; Earth Leakage; Wet Heater Bake out System

Husky Altanium Neo2
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Guide v 1.4 — September 2015 Heating the Mold
Starting the Neo2 System 83
Chapter 10 Heating the Mold
This chapter describes how to start the Neo2 system and check for any errors, and alarm
conditions if any errors occur.
10.1 Starting the Neo2 System
With all Altanium/Neo2 to mold connections made and the mold cooling turned on, Start
Neo2 by touching START in the upper left-hand area of the display. Following this Neo2 will
enter into its startup routine to heat the mold to its setpoint.
10.2 Earth Leakage / Wet Heater Bake Out System
Neo2 is equipped with an advanced Earth Leakage/Wet Heater Bake Out system. From the
moment the system is started, Altanium will constantly check for earth leakage conditions on
every heater in the mold simultaneously. When necessary, it will initiate a low voltage bake
out on the faulty zone(s) to try to bake the moisture out of the heater(s).
There are two types of earth leakages, which are described below.
For X Cards (ICC
2
):
The system will declare an earth leakage error based on a user settable percentage limit,
or if a zone has not gone through diagnostics, based on a default value of 0.2 amps.
The system will declare a bake out error based on a user settable Bake Out Limit with a
default value of 0.2 amps and an adjustable range from 0 to 5 amps. Any value of 0.2
amps or higher, but lower than the earth leakage limit, will trigger a bake out error.
The calculated earth leakage limit or the default value is compared against the
minimum limit and the lower of the two values is applied.
For H Cards (ICC
3
):
The cards include a sensor specifically for monitoring leakage current in the heater
circuit on a continuous basis. The system will declare an earth leakage error based on a
WARNING!
Risk of serious injury, death or equipment damage. Read this entire manual before
attempting the startup of the system. Call the nearest Husky Regional Service and
Sales office if you have any questions.

Table of Contents