Changing the Automatic Manual Control (AMC) Setting 49
User Guide v 1.4 — September 2015 Making Adjustments
7.3.7 Changing the Automatic Manual Control (AMC) Setting
If a thermocouple malfunctions during normal operation, the software can automatically
apply a manual power output percentage to the heater based on the information gathered
before the thermocouple failed. This feature is called Automatic Manual Control (AMC).
If a thermocouple fails and AMC is turned ON (Yes), the control changes the failed zone into
manual mode and sets a manual power output based on the previously recorded average
power output to that heater. If AMC is turned OFF (No), the control skips to PCM (Priority
Control Mode) and performs the designated task. The default setting is ON for all zones.
NOTE:Make sure the present security level is allowed to make this change.
To change the AMC setting:
1. On the Quick Set screen, touch the zone to change.
2. Using the Parameter Scroll buttons, scroll to AMC.
3. Touch AMC to toggle the selected zones from YES to NO or vice versa.
4. Touch OK.
7.3.8 Changing the Power Limit Setting
The Power Limit setting allows the operator to set the maximum amount of power that can
be delivered to the heaters. The default power limit for all zones is 100%.
To change the Power Limit setting for a zone:
1. On the Quick Set screen, touch the zone to adjust.
To select more than one zone, touch the additional zones and they will be selected.
2. Using the Parameter Scroll buttons, scroll to POWER LIMIT.
3. Touch POWER LIMIT and a numerical key window appears.
4. Enter the new value, and then touch Enter. The range is 0% to 100%.
5. Touch OK.
7.3.9 Changing the Earth Leakage Setting
In some cases there may not be a need to check for earth leakage errors on some zones. Neo2
has the ability shut the earth leakage check off on one or more zones in the system. The
default setting is YES on all zones which means all zones are checking for earth leakages
whenever the start button is touched.
NOTE:Make sure the present security level is allowed to make this change.
To change a Earth Leakage setting:
1. On the Quick Set screen, touch the zone to change.
2. Using the Parameter Scroll buttons, scroll to EARTH LEAKAGE.
3. Touch EARTH LEAKAGE to toggle the selected zones from YES to NO or vice versa.
4. Touch OK.