v 1.4 — September 2015 Altanium Neo2
86 Integrated I/O Option (Outputs)
11.2.2 Integrated I/O Option (Outputs)
The table below provides a description of the outputs that are included with the Integrated
I/O option. All outputs are dry contacts; whatever you put in you will get out when the output
is activated. Refer to Table 11-4 for connection details.
CAUTION!
Mechanical hazard - risk of damage to the equipment. DO NOT apply a voltage to any
of the Inputs. Doing so could damage Neo2.
Table 11-1 Integrated I/O Option (Inputs)
Option Name Description
R. STANDBY If the R. STANDBY (Remote Standby) digital input option is turned on, it
will place all zones that have a Remote Standby setpoint set into the
Standby mode whenever this input signal gets activated.
R. BOOST If the R. BOOST (Remote Boost) digital input option is turned on, it will
place all zones that have a Remote Boost setpoint set into the Boost
mode whenever this input signal gets activated.
R. STOP If the R. STOP (Remote Stop) digital input option is turned on, it will STOP
the system whenever this signal is remotely activated. This state will
remain until the START button is selected or Remote Start is activated.
NOTE:You cannot start the system when this input is active.
CAUTION!
Mechanical hazard - risk of damage to the equipment. DO NOT apply a voltage greater
than 120 VAC/VDC (1amp) to any of the Outputs. Doing so could damage Neo2.
Table 11-2 Integrated I/O Option (Outputs)
Option Name Description
ALARM RLY If the Alarm Error dry contact output option is turned on, it will be
activated when an Alarm or Abort condition occurs. This state will
remain until the alarm condition is CLEARED or RESET.
PCM RLY If the PCM dry contact output option is turned on, it will be activated
when an Abort condition occurs, and the PCM setting in the Quick Set
screen is set to System. This state will remain until the alarm condition is
CLEARED or RESET.
AT TEMP If the AT TEMP (at temperature) dry contact output option is turned on,
it will be activated ONLY when all zones are above the Under
Temperature alarm limit. This state will remain until any zone drops
below the Under Temperature alarm limit.