v 1.4 — September 2015 Altanium Neo2
54 Running ART on a Zone
NOTE:The system must be in run mode before a zone can be Re-ARTed.
To ART a zone:
1. On the Quick Set screen, touch the zone to ART.
To select more than one zone, touch the additional zones and they will be selected.
2. Touch Re-ART and the tuning process will begin on the selected zones.
During the ART process the following will be displayed on the zone data buttons:
• 6 Zone Layout — zone number, zone name and ART in the middle of the button.
• 12 Zone Layout — zone number, zone name and ART in the middle of the button.
• 24 Zone Layout — zone number and ART in the middle of the button.
• 48 Zone Layout — zone number and ART in the middle of the button.
The time it takes to ART on a zone is dependent on the time it takes for the heater to heat
up. Small heaters will be the fastest and large manifold heaters will take more time.