Connect for Communication
4
192 809480 Instruction Manual XPR300
How to change the device that has control
The device that first sets a process controls the plasma power supply. For example, if the CNC sets
the process, all other devices that connect to the plasma power supply after the CNC sets the
process can only monitor the data.
If the Client ID and the Operator ID in the XPR web interface are the
same on your device, you are in control of the plasma power supply.
To change the device that has control of the plasma power supply:
1. Remove the power from the cutting system:
a. Set the line-disconnect switch to the OFF position.
b. Make sure that the power-indicator LED is not illuminated on the plasma power supply.
2. Supply power to the cutting system:
a. Set the line-disconnect switch to the ON position.
b. Make sure that the power-indicator LED is illuminated on the plasma power supply.