Connect for Communication
4
XPR300 Instruction Manual 809480 197
Examples of output circuits
Logic interface, active high
Logic interface, active low
Relay interface
This circuit VOIDS the warranty. Do NOT use.
5VDC–24VDC
XPR
C
E
-
+
CNC/PLC
10 k (optional)
High-impedance (≤ 10 mA)
5VDC–24VDC
10 k (optional)
CNC/PLC
XPR
C
E
+
-
High-impedance (≤ 10 mA)
-
CNC +24 V
+24 V
CNC +24 V
XPR
E
C
J17
°t
+
Wire ground
CNC/PLC
External relay
24 VDC low-power coil
≤ 10 mA or ≥ 2400
All relay coils require a freewheeling diode across the relay
coil.
High-current contact closure
inputs (AC or DC)
Install a jumper
(108056)
XPR
Any voltage
C
E
+
-
Power ground