Operation
6
216 809480 Instruction Manual XPR300
Core XPR cutting systems skip the gas-change purge. Core XPR cutting
systems use only process-setup purges. Refer to Process-setup purges
for all XPR cutting systems on page 216.
Process-setup purges for all XPR cutting systems
If you have a cutting system equipped with an OptiMix or VWI gas connect console, a
process-setup purge automatically follows the gas-change purge, and includes preflow and cutflow
purges.
If you have a Core XPR cutting system, the gas-change purge is skipped, and only the
process-setup purge occurs.
The type of process gas used for a process-setup purge is based on the operator-selected
process.