Diagnostics and Troubleshooting
8
XPR300 Instruction Manual 809480 273
530
Alert
Low psi-Line A The Line A pressure (P5)
is less than 75% of the
setpoint for 200
milliseconds, for any
process; or
P5 is less than 75% of
the P21 sensor reading
for 4 seconds, for a
mixed-fuel gas process;
or
P5 is less than 75% of
the P7 setpoint for
4 seconds, for a F5
process.
1. Review the diagnostic code history for previous
pressure-related codes. Previous codes can
indicate where to look for flow or pressure
problems.
2. Make sure that the inlet gas pressure for Line A
(P2) or Line B (P1) are in the correct range.
3. If the measurement is too high or too low, use
the regulators to adjust the pressure for the
Line A/Line B gas or F5 gas to the correct
range.
4. Examine the consumables:
Make sure that the correct consumables are
installed.
Make sure that there is no damage or excess
wear.
5. Replace incorrect consumables or
consumables that have damage or excess wear.
6. Use the gas volume monitors located near the
pressure transducers to look for gas leaks.
Ramp down Set process;
remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action