Diagnostics and Troubleshooting
XPR300 Instruction Manual 809480 293
702
Alert
Shield Gas Inlet N
2
TCC
For a minimum of
200 milliseconds, the
nitrogen (N
2
) inlet pressure
(P4) in the torch connect
console is less than 5.52 bar
(80 psi) or more than
8.61 bar (125 psi).
If you have a cutting system equipped with a Core
or VWI gas connect console, refer to Gas inlet
pressure codes (768 – 771) on page 337.
If you have a cutting system equipped with a
OptiMix gas connect console, refer to Process-gas
inlet pressure in the torch connect console
diagnostic codes (702, 705, 769, 770) for
OptiMix-equipped cutting systems on page 334.
None Set process;
remote on-off
703
Alert
Shield Gas Inlet O
2
TCC
For a minimum of
200 milliseconds, the oxygen
(O
2
) inlet gas pressure (P4) in
the torch connect console is
less than 5.52 bar (80 psi) or
more than 8.61 bar (125 psi).
None Set process;
remote on-off
704
Alert
Shield Gas Inlet Air
TCC
For a minimum of
200 milliseconds, the air inlet
pressure (P4) in the torch
connect console is less than
5.52 bar (80 psi) or more
than 8.61 bar (125 psi).
None Set process;
remote on-off
705
Alert
Shield Gas Inlet
Ar-TCC
For a minimum of
200 milliseconds, the argon
(Ar) inlet pressure (P4) in the
torch connect console is less
than 5.52 bar (80 psi) or
more than 8.61 bar (125 psi).
None Set process;
remote on-off
706
Error
No sensor P1-TCC The P1 pressure sensor in
the torch connect console is
not detected.
Refer to Pressure transducer diagnostic codes
(706 – 715) on page 336.
Ramp down Set process;
remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action
Code cancels
with