4.4 I/O signals
4-13
4. Operation
[LS0] [LS1] signals: Position detection output (backward end / forward end)
● The LS signals perform the same operation as an air cylinder automatic switch.
They are not positioning complete signals.
The LS signals turn ON when the current ELECYLINDER position is within the detection
range configured at the backward and forward ends.
They turn ON when within the detection range regardless of whether the servo is ON or OFF.
The backward end and forward end
set values' relationship to [LS0]
and [LS1] signals ON is as follows.
In this example, the LS signal
detection range is ±0.10 mm.
To adjust the LS signal detection range,
open the [Edit parameters window].
Parameter No.2 [Auto switch LS signal
detection range adjustment] can be used to
make adjustments.
Backward end
0.00 mm
Forward end
150.00 mm
[LS0 detection range]
-0.10 to 0.10 mm
[LS1 detection range]
149.90 to 150.10 mm