EasyManua.ls Logo

IAI ELECYLINDER EC-S13 - Chapter 5 PreventivePredictive Maintenance; Maintenance Information; Total Travel Count; Total Travel Distance

IAI ELECYLINDER EC-S13
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.2 Maintenance information
5-2
5. Preventive/Predictive Maintenance
5.2 Maintenance information
This section introduces three items that can be configured and managed as maintenance
information.
When the set values are exceeded, a "maintenance warning" is issued and the status display LEDs
flash alternately in red and green.
Even if a "maintenance warning" is generated, the ELECYLINDER will continue to operate without
interruption.
Total travel count
Name Symbol Unit Input range
Default setting
at shipping
Total travel count TMCT times 0 to 999, 999,999
0
(disabled setting)
● When the total travel count exceeds the set value, the user will be notified with
"Maintenance warning 1".
● When "Maintenance warning 1" is output, maintenance is recommended, such as
greasing. Set the target value to a value larger than the present one and update.
● Setting it to "0 times" will disable this function.
Total travel distance
Name Symbol Unit Input range
Default setting
at shipping
Total travel distance ODOT m 0 to 999, 999,999
0
(disabled setting)
● When the total travel distance exceeds the set value, the user will be notified with
"Maintenance warning 2".
● When "Maintenance warning 2" is output, maintenance is recommended, such as
greasing. Set the target value to a value larger than the present one and update.
● Setting it to "0 m" will disable this function.
● The displayed units can be switched. (m km)