6.4 Parameter function descriptions
6-7
6. Parameters
Parameter No.2: Auto switch "LS" signal detection range adjustment
No.
Category
Name
Symbol Unit Input range
Default setting
at shipping
2 A
Auto switch "LS"
signal detection
range adjustment
INP mm
Actuator Depended
to 9999.99
0.10
● Sets the backward complete/forward complete ON trigger range relative to the backward
end/forward end.
● When the ELECYLINDER enters the detection range, the backward complete or forward
complete signal turns ON.
● The minimum setting unit is 0.01 mm.
The LS signal detection range for the
conditions below is shown in the figure.
Backward end: 0.00 mm
Forward end: 100.00 mm
Parameter No.2: 0.10 mm
Backward end
0.00 mm
Forward end
100.00 mm
Configuration example
[LS0 detection range]
-0.10 to 0.10 mm
[LS1 detection range]
99.90 to 100.10 mm