EasyManua.ls Logo

IAI ELECYLINDER EC-S13 - Installation of Slider Type; Installation Surface

IAI ELECYLINDER EC-S13
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.3 Installation of Slider type
2-4
2. Installation
2.3 Installation of Slider type
Installation surface
The body mounting surface should be a machined surface or a plane with similar accuracy, with
flatness within 0.05 mm/m.
The installation surface and the body mounting surface not satisfying the flatness requirement
0.05mm/m could increase the sliding resistance, which may cause operation error.
The mounting frame should have a structure rigid enough to prevent the generation of vibration.
Also consider the necessary space for maintenance work such as ELECYLINDER replacement
and inspection.
The bottom surface and left side surface (viewed from motor opposite side) of the body base
serve as the datum surfaces for slider running accuracy. Use these surfaces as the datum
surfaces for mounting when running accuracy is required.
When mounting using the side datum surface, machine the installation surface according to the
figure below.
A dimension
2 to 5 mm
Datum surface effective range
Datum surface
R0.3 or less

Table of Contents