7.4 Troubleshooting by alarm groups
7-20
7. Troubleshooting
Warning: Maintenance warning 1
This is an alert that the target value of the "total travel count" set by the customer has been
reached.
No. Content Countermeasure
1 For safe use and long service life of the
ELECYLINDER, periodic lubrication is
recommended.
* To disable this warning, change the target
value to 0.
[Countermeasure 1]
Perform maintenance and inspection such as
greasing.
→ For details, refer to "8.5 Greasing method".
[Countermeasure 2]
When updating this function, be sure to set the
target value to a value larger than the current
value.
* For setting, refer to "5.2 Maintenance information" and "5.3 Setting maintenance information".
Warning: Maintenance warning 2
This is an alert that the target value of the "total travel distance" set by the customer has
been reached.
No. Content Countermeasure
1 For safe use and long service life of the
ELECYLINDER, periodic lubrication is
recommended.
* To disable this warning, change the target
value to 0.
[Countermeasure 1]
Perform maintenance and inspection such as
greasing.
→ For details, refer to "8.5 Greasing method".
[Countermeasure 2]
When updating this function, be sure to set the
target value to a value larger than the current
value.