10-3
10. Life
10.1 Concept of life for slider type
10.2 Concept of life for controller
10.3 How to take concept of product life for motor drive DC power supply PSA-200
Relation between operation life and moment
The operation life depends on the moment acting on the slider.
With a light load, it may be longer than 10,000 km, the standard rated life.
With no consideration of vibration and mounting conditions, the operation life is 80,000 km
according to the calculation with the formula on the previous page, assuming that 0.5 C
M
(half of
dynamic allowable moment) of moment is applied.
We see that it can be 8 times longer than the standard rated life, which is 10,000 km.
10.2 Concept of life for controller
The controller part affecting service life is as follows.
Target part Life Condition
Electrolytic capacitor 5 years
Ambient temperature 40°C
Rated operation (operation within duty limits)
10.3
How to take concept of product life for motor drive DC power supply PSA-200
The consumable components in the motor drive DC power supply PSA-200 are as shown below.
Target part Life Condition
Electrolytic capacitor 5 years
Ambient temperature 55°C
Continuous rated output
Fan 3 years
Ambient temperature 55°C
Continuous rated output
Relay
100,000
times