(3) Inserting the gateway rack into the network
Insert the rack module by dragging “ANYBUS-S PDP” in the catalog window and dropping it over the master system, as
shown below.
The address is set automatically. To change the address, do so in the Properties dialog box. The address of the gateway
rack must correspond to the address switch setting of the gateway.
<Inserting the rack into the network>
(4) Setting I/O assignments – Inserting the universal module
Insert the universal module into the rack described in the preceding step, as shown below. Since the universal module
provides only up to 64 input bytes and 64 output bytes, another universal module must be inserted if 10 or more axes are
used.
<Inserting the universal module into the rack>