ecification
6.2 Specifications
Model REXT (main unit)
Power-supply voltage
24 VDC
± 10%
Power-supply current MAX 100 mA
Surrounding air temperature
0 to 40
°C
Surrounding humidity 95% RH max. (non-condensing)
Surrounding environment Free from corrosive gases and dust.
Surrounding storage
temperature
0 to 40
°C
Surrounding storage humidity 95% RH max. (non-condensing)
Vibration resistance XYZ directions:
10 to 57 Hz, half amplitude – 0.035 mm (continuous)
0.075 mm (intermittent)
57 to 150 Hz – 4.9 m/s
2
(continuous) / 9.8 m/s
2
(intermittent)
Environment
Impact resistance XYZ directions: 147 mm/s
2
, 11 ms, half-sine wave pulse
Protection degree IP20
Weight 140 g (main unit only)
Outer diameter 34 W x 100 H x 73.3 D [mm]
Caution
The total distance from the GateWayR unit to the downstream SIO link must not exceed 30 m.
When selecting the unit link cables and controller connection cables, make sure the total distance of SIO link does not
exceed 30 m.