Parameter List
‑33‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
F7‑01 0xF701 MF.K key function
selection
0: MF.K key disabled
1: Switchover between
operating panel control and
remote control (terminal or
communication)
2: Switchover between
forward and reverse run
3: Forward jog
4: Reverse jog
0 ‑ At stop "
F7‑01
"
on
page 217
F7‑02 0xF702 STOP/RES key
function
0: STOP/RESET key enabled
only in operating panel
control mode
1: STOP/RESET key enabled in
any operating mode
0 ‑ In real time "
F7‑02
"
on
page 218
F7‑03 0xF703 LED running
display parameter
1
BIT00: Running frequency (Hz)
BIT01: Frequency reference
(Hz)
BIT02: Bus voltage (V)
BIT03: Output voltage (V)
BIT04: Output current (A)
BIT05: Output power (kW)
BIT06: Output torque (%)
0x1F ‑ In real time "
F7‑03
"
on
page 218
Contin
ued
Contin
ued
Continued BIT07: DI status
BIT08: DO status
BIT09: AI1 voltage (V)
BIT10: AI2 voltage (V)
BIT11: AI3 voltage (V)
BIT12: Count value
BIT13: Length value
BIT14: Load speed display
BIT15: PID reference
Contin
ued
Contin
ued
Continued Continued
F7‑04 0xF704 LED running
display parameter
2
BIT00: PID feedback
BIT01: PLC stage
BIT02: Pulse input frequency
(kHz)
BIT03: Running frequency 2
(Hz)
BIT04: Remaining running
time
BIT05: AI1 voltage before
correction (V)
BIT06: AI2 voltage before
correction (V)
0 ‑ In real time "
F7‑04
"
on
page 219