Parameter List
32
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
F6‑26 0xF61A Electromagnetic
shorting current
0% to 200% 100 % In real time "
F6‑26
"
on
page 214
F6‑27 0xF61B Electromagnetic
shorting time
upon startup
0.0s to 100.0s 0 s At stop "
F6‑27
"
on
page 214
F6‑28 0xF61C Electromagnetic
shorting time
upon stop
0.0s to 100.0s 0 s At stop "
F6‑28
"
on
page 215
F6‑29 0xF61D Electromagnetic
shorting voltage
reserve
20.0100.0 V 20 V At stop "
F6‑29
"
on
page 215
F6‑30 0xF61E Trial current for
synchronous
motor speed
tracking
5.0 to 50.0 10 At stop "
F6‑30
"
on
page 215
F6‑31 0xF61F Minimum tracking
frequency for
synchronous
motor speed
tracking
0.0100.0 0 At stop "
F6‑31
"
on
page 215
F6‑32 0xF620 Angle
compensation for
synchronous
motor speed
tracking
0360 0 At stop "
F6‑32
"
on
page 215
F6‑33 0xF621 Proportion of
synchronous
motor speed
tracking
0.110.0 1 At stop "
F6‑33
"
on
page 216
F6‑34 0xF622 Integral of
synchronous
motor speed
tracking
0.110.0 1 At stop "
F6‑34
"
on
page 216
F6‑35 0xF623 Maximum current
limit for DC
braking
80% to 135% 80 % At stop "
F6‑35
"
on
page 216
F6‑36 0xF624 Speed loop
feedforward
‑200.0% to +200.0% 0 % In real time "
F6‑36
"
on
page 216

Table of Contents