Parameter List
‑61‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
A0‑01 0xA001 Torque reference
source
0: Digital setting (A0‑03)
1: AI1
2: AI2
3: AI3
4: Pulse reference (DI5)
5: Communication setting
(1000H)
6: Min. (AI1, AI2)
7: Max. (AI1, AI2)
0 At stop "
A0‑01
"
on
page 322
A0‑03 0xA003 Torque digital
setting
‑200.0% to +200.0% 100 % In real time "
A0‑03
"
on
page 323
A0‑04 0xA004 Torque filter time 0.000s to 5.000s 0 s In real time "
A0‑04
"
on
page 323
A0‑05 0xA005 Speed limit digital
setting
‑120.0% to +120.0% 0 % In real time "
A0‑05
"
on
page 323
A0‑06 0xA006 Frequency
modulation
coefficient in
window mode
0.050.0 0 In real time "
A0‑06
"
on
page 324
A0‑07 0xA007 Torque
acceleration time
0.00s to 650.00s 1 s In real time "
A0‑07
"
on
page 324
A0‑08 0xA008 Torque
deceleration time
0.00s to 650.00s 1 s In real time "
A0‑08
"
on
page 324
A0‑09 0xA009 Speed limit
reference source
0: Set by A0‑05
1: Frequency source
0 In real time "
A0‑09
"
on
page 324
A0‑10 0xA00A Speed limit offset/
Windows
frequency
0.00 Hz to F0‑10 5 Hz In real time "
A0‑10
"
on
page 325
A0‑11 0xA00B Effective mode of
speed limit offset
0: Bidirectional offset valid
1: Unidirectional offset valid
2: Windows mode
1 At stop "
A0‑11
"
on
page 325
A0‑12 0xA00C Frequency
acceleration time
0.0s to 6500.0s 1 s In real time "
A0‑12
"
on
page 325
A0‑13 0xA00D Frequency
deceleration time
0.0s to 6500.0s 1 s In real time "
A0‑13
"
on
page 325
A0‑14 0xA00E Torque mode
switchover
0: No switchover
1: Switched to speed control
at stop
2: Target torque at stop being
0
1 At stop "
A0‑14
"
on
page 326
A1‑00 0xA100 VDO1 function
selection
Same as F4‑00 0 At stop "
A1‑00
"
on
page 326
A1‑01 0xA101 VDI2 function Same as F4‑00 0 At stop "
A1‑01
"
on
page 334
A1‑02 0xA102 VDI3 function Same as F4‑00 0 At stop "
A1‑02
"
on
page 336