Parameter List
‑65‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
A6‑14 0xA60E Curve 5 maximum
input
A6‑12 to 10.00 V 10 V In real time "
A6‑14
"
on
page 360
A6‑15 0xA60F Percentage
corresponding to
curve 5 maximum
input
‑100.0% to +100.0% 100 % In real time "
A6‑15
"
on
page 360
A6‑16 0xA610 AI1 gain ‑10.00 to +10.00 1 ‑ In real time "
A6‑16
"
on
page 360
A6‑17 0xA611 AI1 offset ‑100.0% to +100.0% 0 % In real time "
A6‑17
"
on
page 360
A6‑18 0xA612 AI2 gain ‑10.00 to +10.00 1 ‑ In real time "
A6‑18
"
on
page 361
A6‑19 0xA613 AI2 offset ‑100.0% to +100.0% 0 % In real time "
A6‑19
"
on
page 361
A6‑20 0xA614 AI3 gain ‑10.00 to +10.00 1 ‑ In real time "
A6‑20
"
on
page 361
A6‑21 0xA615 AI3 offset ‑100.0% to +100.0% 0 % In real time "
A6‑21
"
on
page 361
A6‑22 0xA616 AI disconnection
detection
threshold
0.0% to 100.0% 0 % In real time "
A6‑22
"
on
page 362
A6‑23 0xA617 AI disconnection
detection time
0.0s to 6553.5s 0 s In real time "
A6‑23
"
on
page 362
A6‑24 0xA618 Jump point of AI1
setting
‑100.0% to +100.0% 0 % In real time "
A6‑24
"
on
page 362
A6‑25 0xA619 Jump amplitude
set through AI1
0.0% to 100.0% 0.1 % In real time "
A6‑25
"
on
page 362
A6‑26 0xA61A Jump point set
through AI2
‑100.0% to +100.0% 0 % In real time "
A6‑26
"
on
page 363
A6‑27 0xA61B Jump amplitude
set through AI2
0.0% to 100.0% 0.1 % In real time "
A6‑27
"
on
page 363
A6‑28 0xA61C Jump point of AI3
setting
‑100.0% to +100.0% 0 % In real time "
A6‑28
"
on
page 363
A6‑29 0xA61D Jump amplitude
of AI3 setting
0.0% to 100.0% 0.1 % In real time "
A6‑29
"
on
page 363