Parameter List
‑66‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
A6‑30 0xA61E Analog
disconnection
detection
Ones position: AI1
disconnection detection
0: Disabled
1: Enabled
Tens position: AI2
disconnection detection
0: Disabled
1: Enabled
Hundreds position: AI3
disconnection detection
0: Disabled
1: Enabled
0 ‑ In real time "
A6‑30
"
on
page 364
A9‑00 0xA900 Online auto‑tuning
on the rotor time
constant of the
asynchronous
motor
0: Disabled
1: Enabled
0 ‑ In real time "
A9‑00
"
on
page 364
A9‑01 0xA901 Rotor resistance
gain for
asynchronous
motor auto‑tuning
in FVC mode
0–100 5 ‑ In real time "
A9‑01
"
on
page 365
A9‑02 0xA902 Rotor resistance
start frequency for
asynchronous
motor auto‑tuning
in FVC mode
2–100 Hz 7 Hz In real time "
A9‑02
"
on
page 365
A9‑03 0xA903 Magnetic field
efficient for
asynchronous
motor observation
in FVC mode
30–150 40 ‑ In real time "
A9‑03
"
on
page 365
A9‑04 0xA904 Maximum torque
limit coefficient for
the asynchronous
motor field‑
weakening range
30 to 150 80 ‑ In real time "
A9‑04
"
on
page 365
A9‑05 0xA905 Asynchronous
motor speed filter
time in SVC mode
5 ms to 32 ms 15 ms In real time "
A9‑05
"
on
page 366