220 EasyCoder PX4i and PX6i Service Manual
Chapter 17 — Troubleshooting
17.7 Console Errors
Description:
The complete console is “dead”.
Power LED is not lit.
Green background lighting in display window is not lit.
The 5V on the CPU board is OK (see Chapter 15.4).
Possible Causes and Suggested Remedies:
• Defective cable.
- The cable between the CPU board and the console pcb. may be
defective or not properly connected. Check cable and connector J50
on CPU board.
Defective console pcb.
- Replace. Do not attempt to repair.
Description:
No keys on the keyboard seem to be working or no keybeep.
Power LED is lit.
Green background lighting in display window is lit.
Possible Causes and Suggested Remedies:
Bad connection between keypad and console pcb.
- Check connections on the two fl at cables between the keypad and con-
nectors P2 and P3 on console pcb.
Keys disabled or keyboard remapped by a custom-made program (Fin-
gerprint only).
- If the printer does not respond to any keys in the Test Mode, the
keyboard is defective and needs to be replaced.
Keybeep disabled by a custom-made program (Fingerprint only).
- If no beep is heard when the keys are pressed in the Test Mode, but
the printer nevertheless responds to the keys, the beeper is out of
order.
Keyboard damaged by moisture.
- Soaking the keyboard with, for example, water or cleaning fl uids, may
cause short-circuits. Let it dry, replace if necessary.