240 EasyCoder PX4i and PX6i Service Manual
Chapter 17 — Troubleshooting
17.15 Liner Takeup Troubles
Description:
The internal liner takeup unit does not work properly.
Possible Causes and Suggested Remedies:
Bad liner takeup or bad separation of labels from liner at the tear bar.
- Check that the media is routed correctly as described in the User’s
Guide.
- Check that the liner is securely locked to the takeup hub by the brace,
so it cannot slip.
- Check the setup for incorrect media type and feed adjust settings.
Takeup unit slips.
- Spring clutch inside the takeup hub is broken.
- Either the outside of the pulley or the inside of the hub has become
worn.
Either the liner drive roller in the print mechanism or the takeup hub
is not driven by the stepper motor.
- Check if any of the belts from the stepper motor is broken or has
come off the pulleys, see Chapter 9.2.
Neither the liner drive roller in the print mechanism nor the takeup
hub is driven by the stepper motor.
- Check if the stepper motor runs. If not, check as for “Media feed does
not work” in Chapter 17.13.
- Check if both the belts from the stepper motor are broken or have
come off the pulleys, see Chapter 9.2.