222 EasyCoder PX4i and PX6i Service Manual
Chapter 17 — Troubleshooting
17.8 Error Messages
Description:
An error message appears in the display window or is returned via a serial
port.
The printer stops functioning.
The Error LED is usually lit.
• Consult the Intermec Fingerprint v8.xx, Programmer’s Reference Manual
or IPL Programming, Reference Manual for the meaning of the different
error codes and use that information to correct the error.
Depending on the fi rmware, printer’s mode, or running program, there are
different ways of giving the error message.
Immediate Mode (Fingerprint only)
• The rmware can detect and return three error conditions, provided the
printhead is lowered and a media feed is executed.
- Error 1005 (“Out of paper”)
- Error 1027 (“Out of transfer ribbon”)
- Error 1031 (“Next label not found”)
Programming Mode (Fingerprint only)
At every erroneous instruction during programming, the printer trans-
mits an error code on the selected standard OUT channel (serial com-
munication only), provided the verbosity is not disabled. The same
applies if programming errors are detected when the program is run.
When a program is executed, the same errors as in the Immediate Mode
will be detected. The execution stops and an error message is transmit-
ted. It is recommended to included some kind of error handler in any
custom-made application program, for example ERRHAND.PRG.
Intermec Direct Protocol (Fingerprint only)
Eleven error conditions can be detected. Note that by default verbosity
is off in the Intermec Direct Protocol.
- Error 15 ("Font not found")
- Error 18 ("Disc full")
- Error 37 ("Cutter device not found")
- Error 43 ("Memory overfl ow")
- Error 1003 ("Field out of label")
- Error 1005 (“Out of paper”)
- Error 1006 (“No fi eld to print”)
- Error 1022 (“Head lifted”)
- Error 1027 (“Out of transfer ribbon”)
- Error 1031 (“Next label not found”)
- Error 1606 (“Testfeed not done”)
The Intermec Direct Protocol has a programmable error-handler. Refer
to the Intermec Direct Protocol v8.xx, Programmer’s Reference Manual.

Table of Contents

Other manuals for Intermec EasyCoder PX6i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PX6i and is the answer not in the manual?

Intermec EasyCoder PX6i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
DisplayLCD
Product colorSilver
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Media thickness2.4/10 mm
Maximum label width170 mm
Maximum label length4 m
Maximum roll diameter213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Power requirements90 - 265 VAC, 45 - 65Hz
Power consumption (standby)20 W
Power consumption (printing)125 W
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth482 mm
Width238 mm
Height335 mm
Weight14800 g