Table 3.3.7.2-3 STATION GROUP ATTRIBUTES RING GROUPS (PGM 191)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
16
FORCED FWD DEST USAGE
(1:ON/0:OFF): OFF
Enables the system to redirect group calls
to the Forced destination defined under
button 15 above.
0: OFF
1: ON
OFF
17
WAIT IF 1ST ANNC BUSY
(1:ON/0:OFF): ON
When a call assigned to receive an
announcement arrives and all channels are
busy, the call may wait with Ringback until
a channel is available (ON) or bypass the
announcement.
0: OFF
1: ON
ON
18
GROUP NAME
……………………………….
It can be designated a Ring group name.
20
character
….
19
RING Q CALL INDI
0(OFF)1(R/LED)2(LED):1
When a station calls a Ring Group,
DSS/BLF buttons assigned for the calling
station will flash, and the muted ring is
received.
0:OFF
1: R/LED
2: LED
R/LED
20
RING 405RING TONE
00-16 (00: NA)
When a call is routed to a group, the group
member's programmed ring tone is served.
00-16
0
Table 3.3.7.2-4 STATION GROUP ATTRIBUTES EXTERNAL VM GROUPS (PGM 191)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
1
VM 407 WRAP-UP TMR
(000 999) : 002
After terminating any call, the VM port will
be maintained in a busy state for the
duration of the WRAP-UP Timer.
000~999
seconds
002
2
VM 407 PUT MAIL INDEX
(1 4) : 1
For external analog Voice Mail groups, an
index to the Voice Mail Dial Table
1~4
1
3
VM 407 GET MAIL INDEX
(1 4) : 2
An index to the Voice Mail Dial Table
contains the “Get Mail” dial code?
1~4
2
4
VM 407 HUNT TYPE
(1 : CIR/ 0 : TERM): TERM
The type of Hunt process applied to the
SLT ports connected to the VM can be
assigned as Circular or Terminal.
0: TERM
1: CIRC
TERM
5
VM 407 OVERFLOW TMR
(000 - 600) : 180
A call to a group will remain queued to the
group or be sent to the assigned
OVERFLOW DEST after the expiration of
the OVERFLOW TMR.
000~600
seconds
180