EasyManua.ls Logo

ITech IT-M3100 - Esr; Idn

ITech IT-M3100
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Common Commands
Copyright © Itech Electronic Co., Ltd. 81
Example
*ESE 16
Query command
*ESE?
Returns
NR1
See also
*ESR?
*STB?
*ESR?
This command reads the value of Standard Event Status Register (SESR). Once
this command executes, the SESR is reset. The bit definition for the SESR is the
same as the Standard Event Status Enable Register.
Syntax
*ESR?
Arguments
None
Default value
Not applicable
Example
*ESR?
Returns
NR1
See also
*CLS
*ESE
*ESE?
*OPC
*IDN?
This command reads information that identifies the power supply. It returns a
parameter that contains four segments divided by a comma. Example: ITECH Ltd.,
IT3100, 60234567890123456, 1.01-1.02-1.03.