EasyManua.ls Logo

ITech IT-M3100 - [Source:]Current:under:protection:delay <Nrf; [Source:]Current:under:protection:state <Bool

ITech IT-M3100
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Source Commands
Copyright © Itech Electronic Co., Ltd. 22
Default value
MIN
Example
CURR:UND:PROT 0.500
Query command
[SOURce:]CURRent:UNDer:PROTection[:LEVel]? [MINimum|MAXimum]
Returns
<NR3>
[SOURce:]CURRent:UNDer:PROTection:DELay
<NRf+>
This command sets the under-current delay time of the power supply.
Syntax
[SOURce:]CURRent:UNDer:PROTection:DELay <NRf+>
Arguments
<0.00-10.00>
Default value
10.00S
Example
CURR:UND:PROT:DEL 10.000
Query command
[SOURce:]CURRent:UNDer:PROTection:DELay? [MINimum|MAXimum]
Returns
<NR3>
[SOURce:]CURRent:UNDer:PROTection:STATe <bool>
This command enables or disables the under-current function.
Syntax
[SOURce:]CURRent:UNDer:PROTection:STATe <bool>
Arguments
<0|OFF|1|ON>