EasyManua.ls Logo

ITech IT-M3100 - [Source:]External[:State] <Bool; [Source:]Bleeder[:State]

ITech IT-M3100
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Source Commands
Copyright © Itech Electronic Co., Ltd. 36
[SOURce:]EXTernal[:STATe] <bool>
This command enables or disables the external analog quantity function of the
power supply.
Syntax
[SOURce:]EXTernal[:STATe] <bool>
Arguments
0|OFF|1|ON
Default value
Not applicable
Example
EXT 1
Query command
[SOURce:]EXTernal[:STATe]?
Returns
0|1
[SOURce:]BLEeder[:STATe]
This command enables or disables the bleeder circuit function.
Syntax
[SOURce:]BLEeder[:STATe] <bool>
Arguments
0|OFF|1|ON
Default value
Not applicable
Example
BLE ON
Query command
[SOURce:]BLEeder[:STATe]?
Returns
0|1