ITech IT-M3100 - [Source:]Current[:Over]:Protection:state <Bool; [Source:]Current:under:protection[:Level] <Nrf

ITech IT-M3100
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Source Commands
Copyright © Itech Electronic Co., Ltd. 21
Example
CURR:PROT:DEL 10.00
Query command
[SOURce:]CURRent[:OVER]:PROTection:DELay? [MINimum|MAXimum]
Returns
NR3
[SOURce:]CURRent[:OVER]:PROTection:STATe
<bool>
This command enables or disables the over-current function.
Syntax
[SOURce:]CURRent[:OVER]:PROTection:STATe <bool>
Arguments
0|OFF|1|ON
Default value
0
Example
CURR:PROT:STAT ON
Query command
[SOURce:]CURRent[:OVER]:PROTection:STATe?
Returns
0|1
[SOURce:]CURRent:UNDer:PROTection[:LEVel]
<NRf+>
This command sets the under-current limit of the power supply.
Syntax
[SOURce:]CURRent:UNDer:PROTection[:LEVel] <NRf+>
Arguments
<NRf+> MIN TO MAX