Source Commands
Copyright © Itech Electronic Co., Ltd. 19
Chapter7 Source Commands
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
<NRf+>
This command sets the current value of the power supply. The query form of
this command gets the set current value of the power supply.
Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MAX
Example
CURR 3.500
Query command
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returns
NR3
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]
<NRf+>
This command sets the output current value when the power supply receives a
trigger.
Syntax
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MAX
Example
CURR:TRIG 3.500