ITech IT-M3100 - [Source:]Current:slew:negative <Nrf; [Source:]Current:slew:positive <Nrf

ITech IT-M3100
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Source Commands
Copyright © Itech Electronic Co., Ltd. 24
Default value
0.025,0.100
Example
CURR:SLEW 0.030,0.030
Query command
[SOURce:]CURRent:SLEW[:BOTH]?
[MINimum|MAXimum],[MINimum|MAXimum]
Returns
<NR3>,<NR3>
[SOURce:]CURRent:SLEW:NEGative <NRf+>
This command sets the current falling slew rate of the power supply.
Syntax
[SOURce:]CURRent:SLEW:NEGative <NRf+>
Arguments
<0.025-9.999>
Default value
0.100S
Example
CURR:SLEW:NEG 1.000
Query command
[SOURce:]CURRent:SLEW:NEGative? [MINimum|MAXimum]
Returns
NR3
[SOURce:]CURRent:SLEW:POSitive <NRf+>
This command sets the current rising slew rate of the power supply.
Syntax
[SOURce:]CURRent:SLEW:POSitive <NRf+>
Arguments
<0.025-9.999>