[SOURce:]VOLTage:UNDer:PROTection:WARM
<NRf+>
This command sets the under-voltage warm-up time of the power supply.
Syntax
[SOURce:]VOLTage:UNDer:PROTection:WARM <NRf+>
Arguments
<0.00-30.00>
Default value
30.00S
Example
VOLT:UND:PROT:WARM 10.00
Query command
[SOURce:]VOLTage:UNDer:PROTection:WARM? [MINimum|MAXimum]
Returns
NR3
[SOURce:]VOLTage[:LEVel]:LIMit[:HIGH] <NRf+>
This command sets the maximum setting voltage limit of the power supply.
Syntax
[SOURce:]VOLTage[:LEVel]:LIMit[:HIGH] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MAX Limit value
Example
VOLT:LIM 610.00
Query command
[SOURce:]VOLTage[:LEVel]:LIMit[:HIGH]? [MINimum|MAXimum]
Returns
<NR3>