EasyManua.ls Logo

ITech IT-M3100 - [Source:]Voltage:under:protection:delay <Nrf; [Source:]Voltage:under:protection:state <Bool

ITech IT-M3100
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Source Commands
Copyright © Itech Electronic Co., Ltd. 30
[SOURce:]VOLTage:UNDer:PROTection:DELay
<NRf+>
This command sets the under-voltage delay time of the power supply.
Syntax
[SOURce:]VOLTage:UNDer:PROTection:DELay <NRf+>
Arguments
<0.00-10.00>
Default value
10.00S
Example
VOLT:UND:PROT:DEL 10.00
Query command
[SOURce:]VOLTage:UNDer:PROTection:DELay? [MINimum|MAXimum]
Returns
NR3
[SOURce:]VOLTage:UNDer:PROTection:STATe <bool>
This command enables or disables the under-voltage function.
Syntax
[SOURce:]VOLTage:UNDer:PROTection:STATe <bool>
Arguments
0|OFF|1|ON
Default value
0
Example
VOLT:UND:PROT:STAT ON
Query command
[SOURce:]VOLTage:UNDer:PROTection:STATe?
Returns
0|1