EasyManua.ls Logo

ITech IT-M3100 - [Source:]Power:protection[:Level] <Nrf; [Source:]Power:protection:delay <Nrf

ITech IT-M3100
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Source Commands
Copyright © Itech Electronic Co., Ltd. 33
[SOURce:]POWer:PROTection[:LEVel] <NRf+>
This command sets the over-power limit of the power supply.
Syntax
[SOURce:]POWer:PROTection[:LEVel] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MAX
Example
POW:PROT 860.0
Query command
[SOURce:]POWer:PROTection[:LEVel]? [MINimum|MAXimum]
Returns
NR3
[SOURce:]POWer:PROTection:DELay <NRf+>
This command sets the over-power delay time of the power supply.
Syntax
[SOURce:]POWer:PROTection:DELay <NRf+>
Arguments
<0.00-10.00>
Default value
10.00S
Example
POW:PROT:DEL 10.00
Query command
[SOURce:]POWer:PROTection:DELay? [MINimum|MAXimum]
Returns
NR3