Table 19: EX Series Switch Environmental Tolerances
(Connued)
Switch or
device
Environment Tolerance
Altude Relave Humidity Temperature Seismic
EX4550
No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
EX4550-32F switches
— Normal operaon
ensured in the
temperature range 32°
F (0° C) through 113°
F (45° C)
EX4550-32T switches
— Normal operaon is
ensured in the
temperature range 32°
F through 104° F
(40° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX4600 No performance
degradaon to
6,562 feet
(2000 meters)
Normal operaon
ensured in the relave
humidity range 5%
through 90%,
noncondensing
Short-term
operaon ensured in
the relave humidity
range 5% through
93%, noncondensing
NOTE: As dened in
NEBS GR-63-CORE,
Issue 4, short-term
events can be up to
96 hours in duraon
but not more than
15 days per year.
Normal operaon
ensured in the
temperature range 32°
F (0° C) through 113°
F (45° C)
Nonoperang storage
temperature in
shipping container: –
40° F (–40° C)
through 158° F
(70° C)
Complies with
Zone 4
earthquake
requirements per
NEBS GR-63-
CORE, Issue 4.
47