Figure 36: Removing a Lower Rear Fan Tray Before Installing the M120 Router
Removing the Cable Management System
The cable management system is located below the FPC card cage. The cable
management system weighs approximately 5 lb (2.3 kg).
To remove the cable management system (see Figure 37 on page 136):
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to an approved site ESD grounding point. See the instructions for your site.
2. Using a 3/8-in. nut driver, unscrew the nuts on the corners of the cable management
system.
3. Grasp the bottom of the cable management system and pull it straight out from the
studs on the front of the chassis.
135Copyright © 2018, Juniper Networks, Inc.
Chapter 18: Installing the M120 Without a Mechanical Lift