EasyManua.ls Logo

Juniper M120 - Replacing an M120 XENPAK Module

Juniper M120
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver,
number 2.
6. To verify that the CB is functioning normally, check the LEDs on its faceplate. The
green OK LED should light steadily a few minutes after the CB is installed. If the FAIL
LED is lit steadily, remove and install the CB again. If the FAIL LED still lights steadily,
the CB is not functioning properly. Contact your customer support representative.
To check the status of the CB, use the CLI command:
user@host> show chassis environment cb
Figure 75: Installing an M120 CB
See Also M120 Control Board (CB) Description on page 47
M120 Control Board (CB) LEDs on page 48
Related
Documentation
M120 Control Board (CB) Description on page 47
M120 Control Board (CB) LEDs on page 48
205Copyright © 2018, Juniper Networks, Inc.
Chapter 26: Replacing Host Subsystem Components

Table of Contents

Other manuals for Juniper M120