Troubleshooting M120 PICs
Problem Description: The PICs are not functioning normally.
Solution To troubleshoot the PICs:
Check the status of each port on a PIC by looking at the LED located on the PIC
faceplate. For information about the meaning of LED states on different PICs, see the
M120 Multiservice Edge Router Interface Module Reference.
To check the status of a PIC, issue the following CLI command. The PIC slots in the
FPC are numbered from 0 through 3, top to bottom:
user@host> show chassis fpc pic-status
Slot 2 Online M120 FPC Type 1
PIC 2 Present 1x G/E, 1000 BASE-SX- Not Supported
PIC 3 Online 1x Tunnel
Slot 3 Online M120 FPC Type 2
PIC 0 Online 4x OC-3 SONET, SMIR
PIC 1 Present 2x G/E, 1000 BASE-SX- Not Supported
PIC 2 Online 4x G/E SFP, 1000 BASE
PIC 3 Present 1x OC-48 SONET, SMSR- Not Supported
Slot 4 Online M120 FPC Type 3
Slot 5 Online M120 FPC Type 1
PIC 0 Online 1x G/E SFP, 1000 BASE
PIC 2 Online 4x CHDS3 IQ
NOTE: If a PIC does not come online as expected, check the assigned FEB,
as described in “Troubleshooting M120 FEBs” on page 289.
For further description of the output from the command, see the CLI Explorer.
Related
Documentation
M120 PICs Description on page 57
Maintaining M120 PICs and PIC Cables on page 275
Replacing an M120 PIC on page 223
Troubleshooting the M120 Power System
Problem Description: The power supply is not functioning properly.
Copyright © 2018, Juniper Networks, Inc.288