EasyManua.ls Logo

Juniper M120 - Figure 97: Installing an M120 AC Power Supply

Juniper M120
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE: Each AC power supply has two AC appliance inlets. Each power
supply must be connected to a dedicated AC power feed. For 100-120
VAC, both inlets are used. For 200-240 VAC, only the top inlet is used. For
information about site power preparations, see “M120 Router Power
Requirements” on page 88. For information about connecting the router
to power and ground, see “Connecting Power to an AC-Powered M120
Router” on page 167.
13. Switch the power switch on the power supply faceplate to the on position (|). Verify
that the status LED on the power supply faceplate blinks, then lights steadily
approximately one minute after you switch on the power switch.
Figure 97: Installing an M120 AC Power Supply
See Also M120 AC Power Supply Description on page 72
Maintaining the M120 Power Supplies on page 277
Electrical Specifications for the M120 AC Power Supply on page 95
Removing an M120 AC Power Supply on page 239
243Copyright © 2018, Juniper Networks, Inc.