Table 63: LED Indications for Hot-Swappable GPIM Components
DescriptionComponentNumber
The STATUS LED has the following indicators:
•
Solid green indicates that the GPIM is functioning normally.
•
Solid yellow indicates that the GPIM is starting up, running
diagnostics, or going offline.
•
Solid red indicates that the GPIM has failed.
•
Off indicates that the GPIM is not powered on, is offline, or is not
configured.
STATUS LED1
Push the button to turn the GPIM offline. After the STATUS LED light
goes off, it is safe to remove the GPIM from the services gateway.
ONLINE/OFFLINE button2
3. Label the cables connected to the GPIM so that you can later reconnect each cable to the correct GPIM.
4. Disconnect the cables from the GPIM.
5. If necessary, arrange the cables to prevent them from dislodging or developing stress points.
6. Using a Phillips (+) screwdriver, loosen the captive screws on each side of the GPIM faceplate.
7. Grasp the handles on each side of the GPIM faceplate, and slide the GPIM out of the services gateway.
8. Place the GPIM in an electrostatic bag or on an antistatic mat.
9. If you are not reinstalling a GPIM into an empty slot, install a blank GPIM faceplate in the empty slot
to maintain proper airflow.
NOTE: When installing a blank GPIM faceplate, make sure that the padded side of the
faceplate is facing up.
Installing a Gigabit-Backplane Physical Interface Module
Before you begin:
•
Ensure that the services gateway is powered off.
135