1-Port T1/E1 Mini-Physical Interface Module (SRX-MP-1T1E1-R) Hardware
Specifications
Table 26 on page 48 gives the physical specifications of the 1-Port T1/E1 Mini-Physical Interface Module
(Mini-PIM).
Table 26: 1-Port T1/E1 Mini-PIM (SRX-MP-1T1E1-R) Physical Specifications
ValueDescription
0.80 in. x 3.75 in. x 5.9 in.
(2.0 cm x 9.5 cm x 14.5 cm )
Dimensions (H x W x L)
2.88 oz (82 g)Weight
RJ-48Connector type
Mini-PIMForm factor
32°F through 104°F (0°C through 40°C)Environmental operating temperature
–40°F through 158°F (–40°C through 70°C)Storage temperature
5% to 90% noncondensingRelative humidity
1-Port T1/E1 Mini-Physical Interface Module (SRX-MP-1T1E1-R) LEDs
The 1-Port T1/E1 Mini-Physical Interface Module (Mini-PIM) has three LEDs. Table 27 on page 48 describes
the LED states.
Table 27: 1-Port T1/E1 Mini-PIM (SRX-MP-1T1E1-R) LED States
DescriptionStateColorLED
Indicates that there is a local or remote alarm; device
has detected a failure.
OnYellowALARM
Indicates that there are no alarms or failures.Off
Indicates that a loopback or line state is detected.OnYellowLOOPBACK
Indicates that the loopback is not active.Off
48

Table of Contents

Other manuals for Juniper SRX300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX300 Series and is the answer not in the manual?

Juniper SRX300 Series Specifications

General IconGeneral
Memory4 GB
CPUIntel Atom
Storage8 GB
Operating Temperature32°F to 104°F (0°C to 40°C)
Humidity10% to 90% noncondensing

Related product manuals