PR-23 instrucon manual
10.1.1 Transmier program versions
The DTR program version can be updated over the Ethernet connection (see Chap-
ter 12) with K-Patents software. Contact your nearest K-Patents representative for
more information on how to update your DTR program version.
Program version 4.07:
The DTR program version 4.07 is compatible with any K-Patents DTR and any PR-23
sensor with program version 1.00 or higher. This DTR program version contains fol-
lowing new features:
DD-23 Divert Control Unit: protocol versions 2 and 3.
Network booting for sensors: Network booting of sensors from DTR iles.
mA output: Support for negative span for mA output.
Temperature bias: Parameter for temperature bias.
Temperature hold: An ability to hold temperature when concentration is held for
wash or external hold.
Slew rate limit ilter: New output ilter method to limit the maximum change
from a measurement to the next.
Support for advanced http interface
Instrument tags: An option to add instrument tags (max. 16 characters) to trans-
mitter and sensor information.
Wash fail status handling: Wash recovery handling changed so that a wash fail-
ure status is not cleared if wash check was not passed. The error status will be
cleared when the wash check is passed.
Program version 3.0:
The DTR program version 3.0 is compatible with any K-Patents DTR and any PR-23
sensor with program version 1.00 or higher. This DTR program version contains fol-
lowing new features:
Single sensor mode for the intrinsically safe PR-23-...-IA refractometer system
(see Section 9.11). This mode combined with a special single connection H1 inter-
face card PR-10705 creates an Indicating transmitter STR.
Divert functionality enables the DTR to function as a part of a Divert Control
System used to control black liquor concentration in paper and pulp applications.
Divert mode only allows for one sensor per transmitter, but a standard DTR is used.
Program version 2.0:
The DTR program version 2.0 is compatible with any K-Patents DTR and any PR-23
sensor with program version 1.00 or higher. This DTR program version contains fol-
lowing new features:
Instrument homepage and printable veriication certiicate
Multi-lingual user interface
Linear damping
Field sample soft key

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the K-Patents PR-23 and is the answer not in the manual?

K-Patents PR-23 Specifications

General IconGeneral
BrandK-Patents
ModelPR-23
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals